Skip to main content
Advertisement

Main menu

  • Home
  • Content
    • Current Issue
    • Accepted Manuscripts
    • Article Preview
    • Past Issue Archive
    • AJNR Case Collection
    • Case of the Week Archive
    • Classic Case Archive
    • Case of the Month Archive
  • Special Collections
    • Spinal CSF Leak Articles (Jan 2020-June 2024)
    • 2024 AJNR Journal Awards
    • Most Impactful AJNR Articles
  • Multimedia
    • AJNR Podcast
    • AJNR Scantastics
    • Video Articles
  • For Authors
    • Submit a Manuscript
    • Author Policies
    • Fast publishing of Accepted Manuscripts
    • Graphical Abstract Preparation
    • Manuscript Submission Guidelines
    • Imaging Protocol Submission
    • Submit a Case for the Case Collection
  • About Us
    • About AJNR
    • Editorial Board
  • More
    • Become a Reviewer/Academy of Reviewers
    • Subscribers
    • Permissions
    • Alerts
    • Feedback
    • Advertisers
    • ASNR Home
  • Other Publications
    • ajnr

User menu

  • Alerts
  • Log in

Search

  • Advanced search
American Journal of Neuroradiology
American Journal of Neuroradiology

American Journal of Neuroradiology

ASHNR American Society of Functional Neuroradiology ASHNR American Society of Pediatric Neuroradiology ASSR
  • Alerts
  • Log in

Advanced Search

  • Home
  • Content
    • Current Issue
    • Accepted Manuscripts
    • Article Preview
    • Past Issue Archive
    • AJNR Case Collection
    • Case of the Week Archive
    • Classic Case Archive
    • Case of the Month Archive
  • Special Collections
    • Spinal CSF Leak Articles (Jan 2020-June 2024)
    • 2024 AJNR Journal Awards
    • Most Impactful AJNR Articles
  • Multimedia
    • AJNR Podcast
    • AJNR Scantastics
    • Video Articles
  • For Authors
    • Submit a Manuscript
    • Author Policies
    • Fast publishing of Accepted Manuscripts
    • Graphical Abstract Preparation
    • Manuscript Submission Guidelines
    • Imaging Protocol Submission
    • Submit a Case for the Case Collection
  • About Us
    • About AJNR
    • Editorial Board
  • More
    • Become a Reviewer/Academy of Reviewers
    • Subscribers
    • Permissions
    • Alerts
    • Feedback
    • Advertisers
    • ASNR Home
  • Follow AJNR on Twitter
  • Visit AJNR on Facebook
  • Follow AJNR on Instagram
  • Join AJNR on LinkedIn
  • RSS Feeds

Welcome to the new AJNR, Updated Hall of Fame, and more. Read the full announcements.


AJNR is seeking candidates for the position of Associate Section Editor, AJNR Case Collection. Read the full announcement.

 

Research ArticlePatient Safety

Radiation Dose to the Lens Using Different Temporal Bone CT Scanning Protocols

Y. Niu, Z. Wang, Y. Liu, Z. Liu and V. Yao
American Journal of Neuroradiology February 2010, 31 (2) 226-229; DOI: https://doi.org/10.3174/ajnr.A1807
Y. Niu
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Z. Wang
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Y. Liu
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Z. Liu
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
V. Yao
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Info & Metrics
  • Responses
  • References
  • PDF
Loading

Abstract

BACKGROUND AND PURPOSE: Temporal bone CT is performed frequently in clinical practice. At the same time, the eye lens are exposed to ionizing radiation without any useful diagnostic information delivered. Our aim was to investigate the radiation dose to the lens of the eye by using temporal bone CT scanning with different protocols.

MATERIALS AND METHODS: Direct axial and coronal CT by using a conventional sequential scanning mode (140 kV, 220 mAs/section, 1.25-mm thickness, 1.25-mm increment, 16 × 0.625 mm collimation, the glabellomeatal line as a scanning baseline), a routine helical scanning mode (140 kV, 220 mAs/section, 0.315 pitch, 0.67-mm thickness, 0.33-mm increment, 16 × 0.625 collimation, the orbitomeatal line as a scanning baseline), and a modified helical scanning mode (acanthiomeatal line as a scanning baseline; other parameters, same as above) was performed on an exsomatized cadaveric head. CTDIvol and DLP were recorded for each scanning mode, and effective doses were calculated. Organ doses for the lens were measured with TLDs.

RESULTS: When the sequential scanning mode was used, the gross effective dose was 1.21 mSv and the organ dose to the lens was 50.96 and 1.73 mGy, respectively, for direct axial and coronal imaging. The effective dose was 0.803 mSv in routine helical scanning, while the lens dose was 40.17 mGy. With the modified helical scanning mode, the effective dose was as same as that for the routine helical scanning, but the lens dose was reduced significantly to 10.33 mGy.

CONCLUSIONS: The effective doses resulting from sequential axial and coronal scanning were 1.51 times higher than the dose from helical scanning, and the lens dose was 1.31 times higher. With the modified helical scanning mode, thinner section images could be used to reformat axial, coronal, and sagittal images with a further 74.3% reduction in lens dose beyond that achieved with the conventional helical protocol.

Abbreviations

CTDIvol
volume CT dose index
DLP
dose-length product
MSCT
multisection CT
TLD
thermoluminescence dosimeter.
  • Copyright © American Society of Neuroradiology
View Full Text
PreviousNext
Back to top

In this issue

American Journal of Neuroradiology: 31 (2)
American Journal of Neuroradiology
Vol. 31, Issue 2
1 Feb 2010
  • Table of Contents
  • Index by author
Advertisement
Print
Download PDF
Email Article

Thank you for your interest in spreading the word on American Journal of Neuroradiology.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Radiation Dose to the Lens Using Different Temporal Bone CT Scanning Protocols
(Your Name) has sent you a message from American Journal of Neuroradiology
(Your Name) thought you would like to see the American Journal of Neuroradiology web site.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Cite this article
Y. Niu, Z. Wang, Y. Liu, Z. Liu, V. Yao
Radiation Dose to the Lens Using Different Temporal Bone CT Scanning Protocols
American Journal of Neuroradiology Feb 2010, 31 (2) 226-229; DOI: 10.3174/ajnr.A1807

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
0 Responses
Respond to this article
Share
Bookmark this article
Radiation Dose to the Lens Using Different Temporal Bone CT Scanning Protocols
Y. Niu, Z. Wang, Y. Liu, Z. Liu, V. Yao
American Journal of Neuroradiology Feb 2010, 31 (2) 226-229; DOI: 10.3174/ajnr.A1807
del.icio.us logo Twitter logo Facebook logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Purchase

Jump to section

  • Article
    • Abstract
    • Abbreviations
    • Materials and Methods
    • Results
    • Discussion
    • References
  • Figures & Data
  • Info & Metrics
  • Responses
  • References
  • PDF

Related Articles

  • No related articles found.
  • PubMed
  • Google Scholar

Cited By...

  • Impact of Model-Based Iterative Reconstruction on Image Quality of Contrast-Enhanced Neck CT
  • Radiation Dose Reduction in Temporal Bone CT with Iterative Reconstruction Technique
  • Experimental Study and Optimization of Scan Parameters That Influence Radiation Dose in Temporal Bone High-Resolution Multidetector Row CT
  • Crossref (29)
  • Google Scholar

This article has been cited by the following articles in journals that are participating in Crossref Cited-by Linking.

  • Radiation Dose Reduction in Temporal Bone CT with Iterative Reconstruction Technique
    Y.T. Niu, D. Mehta, Z.R. Zhang, Y.X. Zhang, Y.F. Liu, T.L. Kang, J.F. Xian, Z.C. Wang
    American Journal of Neuroradiology 2012 33 6
  • Initial results of a new generation dual source CT system using only an in-plane comb filter for ultra-high resolution temporal bone imaging
    Mathias Meyer, Holger Haubenreisser, Rainer Raupach, Bernhard Schmidt, Florian Lietzmann, Christianne Leidecker, Thomas Allmendinger, Thomas Flohr, Lothar R. Schad, Stefan O. Schoenberg, Thomas Henzler
    European Radiology 2015 25 1
  • Estimation of radiation-induced cataract and cancer risks during routine CT head procedures
    M. Alkhorayef, A. Sulieman, B. Alonazi, M. Alnaaimi, M. Alduaij, D. Bradley
    Radiation Physics and Chemistry 2019 155
  • Radiation dose reduction in soft tissue neck CT using adaptive statistical iterative reconstruction (ASIR)
    Behroze Vachha, Harald Brodoefel, Carol Wilcox, David B. Hackney, Gul Moonis
    European Journal of Radiology 2013 82 12
  • Adult Progressive Sensorineural Hearing Loss
    Deanne M. Roberts, Matthew L. Bush, Raleigh O. Jones
    Otology & Neurotology 2014 35 2
  • Impact of Model-Based Iterative Reconstruction on Image Quality of Contrast-Enhanced Neck CT
    S. Gaddikeri, J.B. Andre, J. Benjert, D.S. Hippe, Y. Anzai
    American Journal of Neuroradiology 2015 36 2
  • Application of a full model-based iterative reconstruction (MBIR) in 80 kVp ultra-low-dose paranasal sinus CT imaging of pediatric patients
    Jihang Sun, Qifeng Zhang, Xiaomin Duan, Chengyue Zhang, Pengpeng Wang, Chenguang Jia, Yong Liu, Yun Peng
    La radiologia medica 2018 123 2
  • Optimization of patient dose and image quality with z-axis dose modulation for computed tomography (CT) head in acute head trauma and stroke
    T. Thomas Zacharia, Sangam G. Kanekar, Dan T. Nguyen, Kevin Moser
    Emergency Radiology 2011 18 2
  • Cochlear implantation in children without preoperative computed tomography diagnostics. Analysis of procedure and rate of complications
    Desiree Ehrmann-Müller, Wafaa Shehata-Dieler, Stefan Kaulitz, Daniela Back, Anja Kurz, Heike Kühn, Rudolf Hagen, Kristen Rak
    International Journal of Pediatric Otorhinolaryngology 2020 138
  • Cumulative organ dose and effective dose in adult population underwent repeated or multiple head CT examination
    Mohd Amirul Azrie Mohd Roslee, Ibrahim Lutfi Shuaib, Ahmad Fakharuddin Mohd Napi, Mohd Amir Syahmi Mat Razali, Noor Diyana Osman
    Radiation Physics and Chemistry 2020 166

More in this TOC Section

  • Safety of Intrathecal Gadobutrol in Various Doses
  • Impact of Kidney Function on CNS Gadolinium Deposition in Patients Receiving Repeated Doses of Gadobutrol
  • Contrast-Induced Acute Kidney Injury in Radiologic Management of Acute Ischemic Stroke in the Emergency Setting
Show more Patient Safety

Similar Articles

Advertisement

Indexed Content

  • Current Issue
  • Accepted Manuscripts
  • Article Preview
  • Past Issues
  • Editorials
  • Editors Choice
  • Fellow Journal Club
  • Letters to the Editor

Cases

  • Case Collection
  • Archive - Case of the Week
  • Archive - Case of the Month
  • Archive - Classic Case

Special Collections

  • Special Collections

Resources

  • News and Updates
  • Turn around Times
  • Submit a Manuscript
  • Author Policies
  • Manuscript Submission Guidelines
  • Evidence-Based Medicine Level Guide
  • Publishing Checklists
  • Graphical Abstract Preparation
  • Imaging Protocol Submission
  • Submit a Case
  • Become a Reviewer/Academy of Reviewers
  • Get Peer Review Credit from Publons

Multimedia

  • AJNR Podcast
  • AJNR SCANtastic
  • Video Articles

About Us

  • About AJNR
  • Editorial Board
  • Not an AJNR Subscriber? Join Now
  • Alerts
  • Feedback
  • Advertise with us
  • Librarian Resources
  • Permissions
  • Terms and Conditions

American Society of Neuroradiology

  • Not an ASNR Member? Join Now

© 2025 by the American Society of Neuroradiology All rights, including for text and data mining, AI training, and similar technologies, are reserved.
Print ISSN: 0195-6108 Online ISSN: 1936-959X

Powered by HighWire