Skip to main content
Advertisement

Main menu

  • Home
  • Content
    • Current Issue
    • Accepted Manuscripts
    • Article Preview
    • Past Issue Archive
    • AJNR Case Collection
    • Case of the Week Archive
    • Classic Case Archive
    • Case of the Month Archive
  • Special Collections
    • Spinal CSF Leak Articles (Jan 2020-June 2024)
    • 2024 AJNR Journal Awards
    • Most Impactful AJNR Articles
  • Multimedia
    • AJNR Podcast
    • AJNR Scantastics
    • Video Articles
  • For Authors
    • Submit a Manuscript
    • Author Policies
    • Fast publishing of Accepted Manuscripts
    • Graphical Abstract Preparation
    • Manuscript Submission Guidelines
    • Imaging Protocol Submission
    • Submit a Case for the Case Collection
  • About Us
    • About AJNR
    • Editorial Board
  • More
    • Become a Reviewer/Academy of Reviewers
    • Subscribers
    • Permissions
    • Alerts
    • Feedback
    • Advertisers
    • ASNR Home
  • Other Publications
    • ajnr

User menu

  • Alerts
  • Log in

Search

  • Advanced search
American Journal of Neuroradiology
American Journal of Neuroradiology

American Journal of Neuroradiology

ASHNR American Society of Functional Neuroradiology ASHNR American Society of Pediatric Neuroradiology ASSR
  • Alerts
  • Log in

Advanced Search

  • Home
  • Content
    • Current Issue
    • Accepted Manuscripts
    • Article Preview
    • Past Issue Archive
    • AJNR Case Collection
    • Case of the Week Archive
    • Classic Case Archive
    • Case of the Month Archive
  • Special Collections
    • Spinal CSF Leak Articles (Jan 2020-June 2024)
    • 2024 AJNR Journal Awards
    • Most Impactful AJNR Articles
  • Multimedia
    • AJNR Podcast
    • AJNR Scantastics
    • Video Articles
  • For Authors
    • Submit a Manuscript
    • Author Policies
    • Fast publishing of Accepted Manuscripts
    • Graphical Abstract Preparation
    • Manuscript Submission Guidelines
    • Imaging Protocol Submission
    • Submit a Case for the Case Collection
  • About Us
    • About AJNR
    • Editorial Board
  • More
    • Become a Reviewer/Academy of Reviewers
    • Subscribers
    • Permissions
    • Alerts
    • Feedback
    • Advertisers
    • ASNR Home
  • Follow AJNR on Twitter
  • Visit AJNR on Facebook
  • Follow AJNR on Instagram
  • Join AJNR on LinkedIn
  • RSS Feeds

Welcome to the new AJNR, Updated Hall of Fame, and more. Read the full announcements.


AJNR is seeking candidates for the position of Associate Section Editor, AJNR Case Collection. Read the full announcement.

 

Research ArticlePatient SafetyF

Low-Dose Temporal Bone CT in Infants and Young Children: Effective Dose and Image Quality

C.B. Nauer, A. Rieke, C. Zubler, C. Candreia, A. Arnold and P. Senn
American Journal of Neuroradiology September 2011, 32 (8) 1375-1380; DOI: https://doi.org/10.3174/ajnr.A2524
C.B. Nauer
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
A. Rieke
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
C. Zubler
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
C. Candreia
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
A. Arnold
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
P. Senn
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Info & Metrics
  • Responses
  • References
  • PDF
Loading

Abstract

BACKGROUND AND PURPOSE: The temporal bone is ideal for low-dose CT because of its intrinsic high contrast. The aim of this study was to retrospectively evaluate image quality and radiation doses of a new low-dose versus a standard high-dose pediatric temporal bone CT protocol and to review dosimetric data from the literature.

MATERIALS AND METHODS: Image quality and radiation doses were compared for 38 low-dose (80 kV/90–110 mAs) and 16 high-dose (140 kV/170 mAs) temporal bone CT scans of infants to 5-year-old children. The CT visualization quality of 23 middle and inner ear structures was subjectively graded by 3 neuroradiologists and 3 otologists by using a 5-point scale with scores 1–2 indicating insufficient and scores 3–5 indicating sufficient image quality. Effective doses of local and literature-derived protocols were calculated from dosimetric data by using NRPB-SR250 software.

RESULTS: Insufficient image-quality scores were more frequent in low-dose scans versus high-dose scans, but the difference was only statistically significant for otologists (6.0% versus 3.4%, P = .004) and not for neuroradiologists (1.2% versus 0.7%, P = .84). Image quality was critical for small structures (such as the stapes or lamella at the internal auditory canal fundus). Effective doses were 0.25–0.3 mSv for low-dose scans, 1.4–1.8 mSv for high-dose scans, and 0.9–2.6 mSv for literature-derived protocols.

CONCLUSIONS: The image quality of the new low-dose protocol remains diagnostic for assessing middle and inner ear anatomy despite a 3- to 8-fold dose reduction over previous and literature-derived protocols. However, image quality of small structures is critical and may be perceived as insufficient.

Abbreviations

CTDI
CT dose index
CTDIvol
volumetric CTDI
CTDIc
CTDI measured in the center
CTDIp
CTDI measured in the periphery
CTDIw
weighted CTDI
Deff
effective dose
DLP
dose-length product
  • © 2011 by American Journal of Neuroradiology
View Full Text
PreviousNext
Back to top

In this issue

American Journal of Neuroradiology: 32 (8)
American Journal of Neuroradiology
Vol. 32, Issue 8
1 Sep 2011
  • Table of Contents
  • Index by author
Advertisement
Print
Download PDF
Email Article

Thank you for your interest in spreading the word on American Journal of Neuroradiology.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Low-Dose Temporal Bone CT in Infants and Young Children: Effective Dose and Image Quality
(Your Name) has sent you a message from American Journal of Neuroradiology
(Your Name) thought you would like to see the American Journal of Neuroradiology web site.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Cite this article
C.B. Nauer, A. Rieke, C. Zubler, C. Candreia, A. Arnold, P. Senn
Low-Dose Temporal Bone CT in Infants and Young Children: Effective Dose and Image Quality
American Journal of Neuroradiology Sep 2011, 32 (8) 1375-1380; DOI: 10.3174/ajnr.A2524

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
0 Responses
Respond to this article
Share
Bookmark this article
Low-Dose Temporal Bone CT in Infants and Young Children: Effective Dose and Image Quality
C.B. Nauer, A. Rieke, C. Zubler, C. Candreia, A. Arnold, P. Senn
American Journal of Neuroradiology Sep 2011, 32 (8) 1375-1380; DOI: 10.3174/ajnr.A2524
del.icio.us logo Twitter logo Facebook logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Purchase

Jump to section

  • Article
    • Abstract
    • Abbreviations
    • Materials and Methods
    • Results
    • Discussion
    • Conclusions
    • Acknowledgments
    • Footnotes
    • References
  • Figures & Data
  • Info & Metrics
  • Responses
  • References
  • PDF

Related Articles

  • No related articles found.
  • PubMed
  • Google Scholar

Cited By...

  • Temporal Bone CT: Improved Image Quality and Potential for Decreased Radiation Dose Using an Ultra-High-Resolution Scan Mode with an Iterative Reconstruction Algorithm
  • Crossref (37)
  • Google Scholar

This article has been cited by the following articles in journals that are participating in Crossref Cited-by Linking.

  • Radiation Dose Reduction at Pediatric CT: Use of Low Tube Voltage and Iterative Reconstruction
    Yasunori Nagayama, Seitaro Oda, Takeshi Nakaura, Akinori Tsuji, Joji Urata, Mitsuhiro Furusawa, Daisuke Utsunomiya, Yoshinori Funama, Masafumi Kidoh, Yasuyuki Yamashita
    RadioGraphics 2018 38 5
  • Preoperative Imaging of Sensorineural Hearing Loss in Pediatric Candidates for Cochlear Implantation
    Joseph Y. Young, Maura E. Ryan, Nancy M. Young
    RadioGraphics 2014 34 5
  • Temporal Bone CT: Improved Image Quality and Potential for Decreased Radiation Dose Using an Ultra-High-Resolution Scan Mode with an Iterative Reconstruction Algorithm
    S. Leng, F.E. Diehn, J.I. Lane, K.K. Koeller, R.J. Witte, R.E. Carter, C.H. McCollough
    American Journal of Neuroradiology 2015 36 9
  • Spectral Shaping Via Tin Prefiltration in Ultra-High-Resolution Photon-Counting and Energy-Integrating Detector CT of the Temporal Bone
    Jan-Peter Grunz, Julius Frederik Heidenreich, Simon Lennartz, Jens Philipp Weighardt, Thorsten Alexander Bley, Süleyman Ergün, Bernhard Petritsch, Henner Huflage
    Investigative Radiology 2022 57 12
  • High-resolution cone-beam computed tomography: a potential tool to improve atraumatic electrode design and position
    Sharon L. Cushing, Michael J. Daly, Claudiu G. Treaba, Harley Chan, Jonathan C. Irish, Susan Blaser, Karen A. Gordon, Blake C. Papsin
    Acta Oto-Laryngologica 2012 132 4
  • Comparison of simulated cone beam computed tomography to conventional helical computed tomography for imaging of rhinosinusitis
    Saeed Fakhran, Lea Alhilali, Gayathri Sreedher, Andreea C. Dohatcu, Stella Lee, Berrylin Ferguson, Barton F. Branstetter
    The Laryngoscope 2014 124 9
  • Prevalence of Extracochlear Electrodes: Computerized Tomography Scans, Cochlear Implant Maps, and Operative Reports
    Jourdan T. Holder, David M. Kessler, Jack H. Noble, René H. Gifford, Robert F. Labadie
    Otology & Neurotology 2018 39 5
  • Flat-panel CT versus 128-slice CT in temporal bone imaging: Assessment of image quality and radiation dose
    Lorenzo Piergallini, Elisa Scola, Bruno Tuscano, Roberto Brambilla, Mauro Campoleoni, Gabriella Raimondi, Luciano Lombardi, Federica Di Berardino, Diego Zanetti, Clara Sina, Fabio Triulzi, Giorgio Conte
    European Journal of Radiology 2018 106
  • The accuracy of ultrashort echo time MRI sequences for medical additive manufacturing
    Maureen van Eijnatten, Erik-Jan Rijkhorst, Mark Hofman, Tymour Forouzanfar, Jan Wolff
    Dentomaxillofacial Radiology 2016 45 5
  • Do Measurements of Inner Ear Structures Help in the Diagnosis of Inner Ear Malformations? A Review of Literature
    Felice D’Arco, Giacomo Talenti, Rahul Lakshmanan, Kate Stephenson, Ata Siddiqui, Olivia Carney
    Otology & Neurotology 2017 38 10

More in this TOC Section

  • Safety of Intrathecal Gadobutrol in Various Doses
  • Impact of Kidney Function on CNS Gadolinium Deposition in Patients Receiving Repeated Doses of Gadobutrol
  • Contrast-Induced Acute Kidney Injury in Radiologic Management of Acute Ischemic Stroke in the Emergency Setting
Show more Patient Safety

Similar Articles

Advertisement

Indexed Content

  • Current Issue
  • Accepted Manuscripts
  • Article Preview
  • Past Issues
  • Editorials
  • Editors Choice
  • Fellow Journal Club
  • Letters to the Editor

Cases

  • Case Collection
  • Archive - Case of the Week
  • Archive - Case of the Month
  • Archive - Classic Case

Special Collections

  • Special Collections

Resources

  • News and Updates
  • Turn around Times
  • Submit a Manuscript
  • Author Policies
  • Manuscript Submission Guidelines
  • Evidence-Based Medicine Level Guide
  • Publishing Checklists
  • Graphical Abstract Preparation
  • Imaging Protocol Submission
  • Submit a Case
  • Become a Reviewer/Academy of Reviewers
  • Get Peer Review Credit from Publons

Multimedia

  • AJNR Podcast
  • AJNR SCANtastic
  • Video Articles

About Us

  • About AJNR
  • Editorial Board
  • Not an AJNR Subscriber? Join Now
  • Alerts
  • Feedback
  • Advertise with us
  • Librarian Resources
  • Permissions
  • Terms and Conditions

American Society of Neuroradiology

  • Not an ASNR Member? Join Now

© 2025 by the American Society of Neuroradiology All rights, including for text and data mining, AI training, and similar technologies, are reserved.
Print ISSN: 0195-6108 Online ISSN: 1936-959X

Powered by HighWire