PT - JOURNAL ARTICLE AU - Fulbright, R AU - Panush, D AU - Sze, G AU - Smith, R C AU - Constable, R T TI - MR of the head and neck: comparison of fast spin-echo and conventional spin-echo sequences. DP - 1994 Apr 01 TA - American Journal of Neuroradiology PG - 767--773 VI - 15 IP - 4 4099 - http://www.ajnr.org/content/15/4/767.short 4100 - http://www.ajnr.org/content/15/4/767.full SO - Am. J. Neuroradiol.1994 Apr 01; 15 AB - PURPOSE To compare conspicuousness of head and neck lesions on fast spin-echo sequences and conventional spin-echo sequences. METHODS Forty consecutive patients with 61 head and neck lesions were evaluated. Lesion conspicuousness was qualitatively compared on conventional spin-echo and fast spin-echo sequences, using both spin-density and T2-weighted images. Thirty-six lesions had surgical or pathologic confirmation, and 25 were assigned a presumptive diagnosis based on clinical evaluation and imaging findings seen on conventional spin-echo T1- and T2-weighted sequences. Forty lesions were related to neoplasms; 21 lesions consisted of infectious, vascular, or inflammatory abnormalities. RESULTS Fast spin-echo sequences provided improved lesion conspicuousness in 91% of spin-density images, in 77% of T2-weighted images, and in 84% of the combined spin-density and T2-weighted images. CONCLUSION By providing shorter imaging times and equal or superior lesion conspicuousness, long-repetition-time fast spin-echo sequences can replace long-repetition-time conventional spin-echo sequences in evaluation of the head and neck.