Research ArticleINTERVENTIONAL
Aneurysmal Rupture during Embolization with Guglielmi Detachable Coils: Causes, Management, and Outcome
Arnd Doerfler, Isabel Wanke, Thomas Egelhof, Uwe Dietrich, Siamak Asgari, Dietmar Stolke and Michael Forsting
American Journal of Neuroradiology November 2001, 22 (10) 1825-1832;
Arnd Doerfler
Isabel Wanke
Thomas Egelhof
Uwe Dietrich
Siamak Asgari
Dietmar Stolke

References
- ↵Serbinenko FA. Balloon catheterization and occlusion of major cerebral vessels. J Neurosurg 1974;41:125-145
- Guglielmi G, Viñuela F, Sepetka I, Macellari V. Electrothrombosis of saccular aneurysms via endovascular approach, I: electrochemical basis, technique, and experimental results. J Neurosurg 1991;75:1-7
- ↵Viñuela F, Duckwiler G, Mawad M. Guglielmi detachable coil embolization of acute intracranial aneurysm: perioperative anatomical and clinical outcome in 403 patients. J Neurosurg 1997;86:475-482
- ↵Raymond J, Roy D. Safety and efficacy of endovascular treatment of acutely ruptured aneurysms. Neurosurgery 1997;41:1235-1246
- ↵Cognard C, Weill A, Castaings L, Rey A, Moret J. Intracranial berry aneurysms: angiographic and clinical results after endovascular treatment. Radiology 1998;206:499-510
- ↵Brilstra EH, Rinkel GJ, van der Graaf Y, van Rooij WJ, Algra A. Treatment of intracranial aneurysms by embolization with coils: a systematic review. Stroke 1999;30:470-476
- ↵McDougall C, Halbach VV, Dowd CF, Higashida RT, Larsen DW, Hieshima GB. Endovascular treatment of basilar tip aneurysms using electrolytically detachable coils. J Neurosurg 1996;84:393-399
- Halbach VV, Higashida R, Dowd C, Barnwell SL, Hieshima GB. Management of vascular perforations that occur during neurointerventional procedures. AJNR Am J Neuroradiol 1991;12:319-327
- ↵McDougall C, Halbach VV, Dowd C, Higashida R, Larsen D, Hieshima G. Causes and management of aneurysmal hemorrhage occuring during embolization with Guglielmi detachable coils. J Neurosurg 1998;89:87-92
- ↵Valavanis A, Machado E, Chen JJ. Aneurysm rupture during GDC treatment: incidence, management and outcome. Neuroradiology 1996;38: (suppl 2) 45
- ↵Ricolfi F, Le Guerinel C, Blustajn J, et al. Rupture during treatment of recently ruptured aneurysms with Guglielmi electrodetachable coils. AJNR Am J Neuroradiol 1998;19:1653-1658
- ↵Beamer YB, Corsino JF, Lynde RG. Rupture of aneurysm of the internal carotid artery during arteriography with filling of subarachnoid space and demonstration of a temporal lobe mass: case report. J Neurosurg 1969;31:224-226
- Komiyama M, Tamura K, Nagata Y, Fu Y, Yagura H, Yasui T. Aneurysmal rupture during angiography. Neurosurgery 1993;33:798-803
- Saitoh H, Hayakawa K, Nishimura K, et al. Rerupture of cerebral aneurysm during angiography. AJNR Am J Neuroradiol 1995;16:539-542
- ↵Lin JP, Kricheff II, Chaes NE. Blood pressure changes during retrograde brachial angiography. Radiology 1964;83:640-646
- Sorimachi T, Takeuchi S, Koike T, Minakawa T, Tanaka R. Intra-aneurysmal pressure changes during angiography in coil embolization. Surg Neurol 1997;48:451-457
- ↵Batjer H, Samson D. Intraoperative aneurysmal rupture: incidence, outcome, and suggestions for surgical management. Neurosurgery 1986;18:701-707
- ↵Houkin K, Kuroda S, Takahashi A, et al. Intra-operative premature rupture of cerebral aneurysms: analysis of the causes and management. Acta Neurochir (Wien) 1999;141:1255-1263
- ↵Willinsky R, terBrugge K. Use of a second microcatheter in the management of a perforation during endovascular treatment of a cerebral aneurysm. AJNR Am J Neuroradiol 2000;21:1537-1539
- ↵Qureshi AI, Luft AR, Sharma M, Guterman LR, Hopkins LN. Prevention and treatment of thromboembolic and ischemic complication associated with endovascular procedures, II: clinical aspects and recommendations. Neurosurgery 2000;46:1360-1376
- ↵Guglielmi G, Viñuela F, Duckwiler G. Endovascular treatment of posterior circulation aneurysms by electrothrombosis using electrically detachable coils. J Neurosurg 1992;77:515-524
In this issue
Advertisement
Arnd Doerfler, Isabel Wanke, Thomas Egelhof, Uwe Dietrich, Siamak Asgari, Dietmar Stolke, Michael Forsting
Aneurysmal Rupture during Embolization with Guglielmi Detachable Coils: Causes, Management, and Outcome
American Journal of Neuroradiology Nov 2001, 22 (10) 1825-1832;
0 Responses
Jump to section
Related Articles
- No related articles found.
Cited By...
- Safety and efficacy of management for intraprocedural rupture during endovascular treatment for intracranial aneurysms
- Vessel perforation during stent retriever thrombectomy for acute ischemic stroke: technical details and clinical outcomes
- Cerebral aneurysm wall thickness analysis using intraoperative microscopy: effect of size and gender on thin translucent regions
- Endovascular coil embolization of a very small ruptured aneurysm using a novel microangiographic technique: technical note
- A checklist for cerebral aneurysm embolization complications
- Intraprocedural Aneurysmal Rupture during Coil Embolization of Brain Aneurysms: Role of Balloon-Assisted Coiling
- Repair of intracranial vessel perforation with Onyx-18 using an exovascular retreating catheter technique
- A Checklist in the Event of Aneurysm Perforation during Coiling
- Clinical and Angiographic Results of Coiling of 196 Very Small (<= 3 mm) Intracranial Aneurysms
- Predictors and Outcomes of Intraprocedural Rupture in Patients Treated for Ruptured Intracranial Aneurysms: The CARAT Study
- Intravenous Administration of Acetylsalicylic Acid During Endovascular Treatment of Cerebral Aneurysms Reduces the Rate of Thromboembolic Events
This article has not yet been cited by articles in journals that are participating in Crossref Cited-by Linking.
More in this TOC Section
Similar Articles
Advertisement